knife switches power resistors

AC Crane Applications by Filnor, Inc

AC mill duty and industrial duty crane control.
  load banks power resistors
industrial electrical products

AC CRANE APPLICATIONS

 
While viewing a product line, click "Get Quote" to receive a quote sent to the email address you provide. Certain situations may require we contact you regarding your quote request.

Control Equipment


filnor literature AC Crane Control

PRIVATE FILNOR LOGIN


 
Newsletter Signup
Receive eNews from Filnor
Customer Service
support@filnor.com
Privacy Policy
Customer Login
Customer Login
Register
Forgot Password?
Contact Us
227 N. Freedom
Alliance, Ohio 44601, U.S.A.
Phone: 330-821-7667
Fax: 330-829-3175
info@filnor.com
 
AC MILL DUTY CRANE CONTROL

ac panelboardFilnor Inc. Class 3010 and Class 3011 AC Magnetic Heavy Duty Crane Control for Hoist, Trolley and Bridge Service. NEMA Class I Service, CMAA Classification D, E, & F Service.

Filnor Inc. Class 3010 Hoist Controller and Class 3011 Travel Controllers are recommended for use with AC Wound Rotor Motors. Applications include HEAVY or SEVERE Duty Cranes; Magnet or Bucket Cranes.

• Mill Duty Clapper Type Contactors used throughout Controllers.
• Nema 1 Enclosure Standard
• Customer Specified Component Manufacturer


CLASS 3010 HOIST CONTROL SYSTEMS

Type “R” - Reversing for use with Mechanical Load Brake.

Type “DL” - Reversing Dynamic Lowering using Single Phase Motor Connection. Suitable for Applications NOT requiring Slow Lowering Speeds.

Type “ECB” - Reversing with Eddy Current Electric Load Brake. Provides Slow Hoisting and Lowering for ALL Loads.

Type “CT” - Reversing Counter Torque, Provides Slow Hoisting and Lowering Speeds for Overhauling Loads ONLY. Recommended for Magnet or Bucket Cranes.

REQUIRED INFORMATION

MAIN HOIST MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage - ( )
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, DL, ECB, CT )
Are Drawings Available ( YES, NO )
Manufacturer of Hoist Control Scheme ( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)

AUXILIARY HOIST MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage - ( )
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, DL, ECB, CT )
Are Drawings Available ( YES, NO )
Manufacturer of Hoist Control Scheme ( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )

CLASS 3011 TRAVEL CONTROL SYSTEMS

Type “R” - Reversing Control
Type “RP” - Reversing Plugging
Type “DRP” - Duplex Reversing Plugging

TROLLEY MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage - ( )
Number of Speeds ( 1 thru 6 )
Type of Trolley Control ( R, RP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )

BRIDGE MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage - ( )
Number of Speeds ( 1 thru 6)
Type of Bridge Control ( R, RP, DRP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)

MANUAL MAGNETIC DISCONNECT SWITCH

Total Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
DC Crane Applications



ac panelboardAC INDUSTRIAL DUTY CRANE CONTROL

Filnor Inc. Class 3200 AC Industrial Duty Crane Control for Hoist, Trolley and Bridge Service.

NEMA Class I. II Service, CMAA Classification A, B, C, & D Service.
Filnor Inc. Class 3200 Hoist Controller
and Travel Controllers are recommended
for use with AC Wound Rotor Motors. Applications include HEAVY DUTY or GENERAL DUTY Cranes.

• Industrial Duty Vertical Lift Type Contactors used throughout Controllers.
• Nema 1 Enclosure Standard
• Customer Specified Component Manufacturer


CLASS 3200 HOIST CONTROL SYSTEMS

Type “R” - Reversing for use with Mechanical Load Brake.
Type “DL” - Reversing Dynamic Lowering using Single Phase Motor Connection. Suitable for Applications NOT requiring Slow Lowering Speeds.
Type “ECB” - Reversing with Eddy Current Electric Load Brake. Provides Slow Hoisting and Lowering for ALL Loads.

INFORMATION REQUIRED

MAIN HOIST MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Voltage - ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, DL, ECB )
Are Drawing Available ( YES, NO )
Manufacturer of Hoist Control Scheme
( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)

AUXILIARY HOIST MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Voltage - ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, DL, ECB )
Are Drawings Available ( YES, NO)
Manufacturer of Hoist Control Scheme
( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)

CLASS 3011 TRAVEL CONTROL SYSTEMS

Type “R” - Reversing Control
Type “RP” - Reversing Plugging
Type “DRP” - Duplex Reversing Plugging

TROLLEY MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Voltage - ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Trolley Control ( R, RP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)

BRIDGE MOTION

Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Motor Primary Amps ( )
Motor Secondary Voltage - ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Bridge Control ( R, RP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )

MAIN LINE EQUIPMENT

Total Horsepower ( )
Motor Primary Voltage - ( 575V, 480V or 230V )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
- Thru-the-Door Operator ( Unfused or Fused )


Filnor.com | Contact Us | Register | Forgot Password? | Privacy Policy | Conditions Of Sale


Filnor, Inc.    2012 © All Rights Reserved
     Filnor, Inc. is a Certified ISO 9001 Company.knife switches power resistors

Monday February 6, 2012    17:49:5


Power Resistors | Disconnect Switches | Control Equipment | Load Banks | Resistor Designs | Transit Products | Fuse Blocks | Site Map