AC CRANE APPLICATIONS
 

AC MILL DUTY CRANE CONTROL
Filnor Inc. Class 3010 and Class 3011 AC Magnetic Heavy Duty Crane Control for Hoist, Trolley and Bridge Service. NEMA Class I Service, CMAA Classification D, E, & F Service.
Filnor Inc. Class 3010 Hoist Controller and Class 3011 Travel Controllers are Recommended for use with AC Wound Rotor Motors. Applications include HEAVY or SEVERE Duty Cranes; Magnet or Bucket Cranes.
Mill Duty Clapper Type Contactors used Throughout Controllers.
Nema 1 Enclosure Standard
Customer Specified Component Manufacturer
CLASS 3010 HOIST CONTROL SYSTEMS
Type R - Reversing for use with Mechanical Load Brake.
Type DL - Reversing Dynamic Lowering using Single Phase Motor Connection. Suitable for Applications NOT requiring Slow Lowering Speeds.
Type ECB - Reversing with Eddy Current Electric Load Brake. Provides Slow Hoisting and Lowering for ALL Loads.
Type CT - Reversing Counter Torque, Provides Slow Hoisting and Lowering Speeds for Overhauling Loads ONLY. Recommended for Magnet or Bucket Cranes.
REQUIRED INFORMATION
MAIN HOIST MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage ( )
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, DL, ECB, CT )
Are Drawing Available ( YES, NO )
Manufacturer of Hoist Control Scheme ( SQUARED, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
AUXILIARY HOIST MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage ( )
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, DL, ECB, CT )
Are Drawing Available ( YES, NO )
Manufacturer of Hoist Control Scheme ( SQUARED, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )
CLASS 3011 TRAVEL CONTROL SYSTEMS
Type R - Reversing Control
Type RP - Reversing Plugging
Type DRP - Duplex Reversing Plugging
TROLLEY MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage ( )
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, RP )
Are Drawing Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )
BRIDGE MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Amps ( )
Motor Secondary Amps ( )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage ( )
Number of Speeds ( 1 thru 6)
Type of Hoist Control ( R, RP, DRP )
Are Drawing Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
MANUAL MAGNAETIC DISCONNECT SWITCH
Total Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V. )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
|
|

AC INDUSTRIAL DUTY CRANE CONTROL
Filnor Inc. Class 3200 AC Industrial Duty Crane Control for Hoist, Trolley and Bridge Service.
NEMA Class I. II Service, CMAA Classification A, B, C, & D Service.
Filnor Inc. Class 3200 Hoist Controller
and Travel Controllers are Recommended
for use with AC Wound Rotor Motors. Applications include HEAVY DUTY or GENERAL DUTY Cranes.
Industrial Duty Vertical Lift Type Contactors used Throughout Controllers.
Nema 1 Enclosure Standard
Customer Specified Component Manufacturer
CLASS 3200 HOIST CONTROL SYSTEMS
Type R - Reversing for use with Mechanical Load Brake.
Type DL - Reversing Dynamic Lowering using Single Phase Motor Connection. Suitable for Applications NOT requiring Slow Lowering Speeds.
Type ECB - Reversing with Eddy Current Electric Load Brake. Provides Slow Hoisting and Lowering for ALL Loads.
INFORMATION REEQUIRED
MAIN HOIST MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V. )
Motor Primary Amps ( )
Motor Secondary Voltage ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, DL, ECB )
Are Drawing Available ( YES, NO
)Manufacturer of Hoist Control Scheme
( SQUARED, CUTLER-HAMMER,
WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
AUXILIARY HOIST MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Voltage ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, DL, ECB )
Are Drawing Available ( YES, NO)
Manufacturer of Hoist Control Scheme
( SQUARED, CUTLER-HAMMER,
WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
CLASS 3011 TRAVEL CONTROL SYSTEMS
Type R - Reversing Control
Type RP - Reversing Plugging
Type DRP - Duplex Reversing Plugging
TROLLEY MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Voltage ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, RP )
Are Drawing Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
BRIDGE MOTION
Quantity of Motors ( )
Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Motor Primary Amps ( )
Motor Secondary Voltage ( )
Motor Secondary Amps ( )
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, RP )
Are Drawing Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )
MAIN LINE EQUIPMENT
Total Horsepower ( )
Motor Primary Voltage ( 575V., 480V. or 230V.)
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Main Disconnect
- Knife Switch ( Unfused or Fused )
- Circuit Breaker
- Thru-the-Door Operator ( Unfused or Fused ) |